Fixed Gas & Flame Detection

HazardWatch II Fire and Gas System

HazardWatch II is the SIL 2 capable, pre-engineered Fire and Gas Detection System representing the next generation in highly intelligent monitoring solutions designed to help reduce hazard vulnerability and meet the most demanding global safety standards. The system meets the market need for a well integrated and NRTL tested complete solution for fire and gas detection, fire suppression, and related safety instrumented functions.
view details

Zero Two Series Gas and Flame Detection System

Modular system offering the widest range of control cards for use in an integrated fire and/or gas detection system. The Zero Two Series system can monitor any combination of the following: combustible gas, H2S, toxic gas, ultrasonic, oxygen deficiency and flame detection. In addition, its open architecture allows the system to accommodate other sensing devices for tasks such as smoke detection, heat detection and manual call points. 
view details

TA202A Single Channel H2S Trip Amplifier Module

The TA202A is a single-channel H2S Trip Amplifier Module for use with our H2S Intelligent Sensors. It is designed to monitor H2S in parts per million (ppm) levels and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through front panel interface (mode / select switch and digital display).
view details

2280A Four Channel H2S Gas Monitor

The 2280A is a system for continuously monitoring H2S gas concentrations in four locations. The system consists of up to four remote mounted sensors and a solid state controller. The controller consists of four independent channels, each having its own circuitry. With a digital display, the 2280A shows hydrogen sulfide gas concentrations in ppm (parts per million) in the ranges of 0-20, 0-50, or 0-99 ppm for each channel.
view details

2602A Zero Two Series Control Module for H2S Applications

The 2602A is a single-channel H2S Control Module that has been designed to monitor H2S in parts per million (ppm) levels and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through front panel interface (mode / select switch and digital display). The digital display on the 2602A indicates hydrogen sulfide gas concentration, fault codes, calibration cues and setup options. Other features include LED indications of status, relay outputs for fault, low alarm and high alarm, and serial communications ports.
view details

H2S Gas Sensors and Accessories

General Monitorsʼ hydrogen sulfide (H2S) sensors are solid state devices, designed and manufactured for long life and fast response. They are selective to H2S and remain unaffected by high concentrations of other substances like hydrogen, sulfur dioxide, and gasoline vapors, which are often present in facilities that process sour gas and crude oil. A high tolerance to a broad range of temperatures and humidity enable these sensors to operate in rugged environments, as does their capacity to withstand exposure to high H2S concentrations over short periods.
view details

Electrochemical Sensors

The General Monitors electrochemical gas sensors are highly sensitive to toxic gases including carbon monoxide, H2S, hydrogen, hydrogen chloride, ammonia, chlorine, chlorine dioxide,  nitric oxide, nitrogen dioxide, ozone, SO2, and oxygen deficiency.
view details

Observer-i Ultrasonic Gas Leak Detector

Instantly detect pressurized gas leaks with this high-precision,  omni-direction acoustic detector utilizing Gassonic ultrasonic technology. Works even when traditional methods of gas detection are unsuitable or dependent on ventilation. Features Artificial Neural  Network (ANN) technology that distinguishes between real gas leaks and false  alarm sources without requiring any in-field training. The Observer-i UGLD provides an industry-leading detection range (up to 28 m) reducing the  number of detectors required. Ideal for use in complex, outdoor pipeline systems.
view details

TA502A Single Channel Trip Amplifier Module

The TA502A is a single-channel generic trip amplifier designed for use in Zero Two Series Gas and Flame Detection Systems. It is used to process the 0-22 mA signal from any field mounted transmitter.
view details

Toxic Gas Accessories

General Monitors offers a wide variety of accessories for our toxic gas detectors.
view details

CC02A Serial Communications Module

The CC02A Communications Card facilitates serial communications between each module in a Zero Two Series Flame and Gas Detection System and an external host computer, which allows fast access to operational and setup data registers. It supports a Burst Read feature that returns all registers of a module in a single transmission.
view details

DT210 Eight Channel H2S Readout / Relay Module

The DT210 is an eight-channel Readout / Relay Module designed for use with up to eight of our remotely located H2S Intelligent Sensors. The front panel contains a digital display that indicates 0-20 ppm (parts per million), 0-50 ppm, or 0-99 ppm of the hydrogen sulfide gas monitored by the Intelligent Sensors.
view details

FM002A Facilities Module

The FM002A is a facilities module that provides a range of common facilities for all Zero Two control modules housed in the chassis. The FM002A is plugged into the last slot on the right-hand side of the Zero Two chassis. It may be daisy-chained allowing one FM002A to serve up to 100 Zero Two modules in any combination.
view details

IN042 Four Zone Control Module

The IN042 is a four zone input module designed for use with two-wire field devices such as smoke or heat detectors, pull switches and manual callpoints. It is designed to monitor these devices and provide both status indication and fault / alarm outputs for each zone.
view details

TS4000H Toxic Gas Detector

The TS4000H Intelligent Toxic Gas Detector continuously monitors a variety of toxic gases in the ppm range or oxygen deficiency, delivering highly accurate detection and protection. The unit features one person calibration and virtually self-calibrates by simply activating a magnetic switch and applying gas. It provides status indication and alarm outputs. Configurations with relays, Modbus, and HART are available to meet many needs.
view details

MD002 Monitored Driver Output Module

The MD002 is a monitored driver output module designed for four independent outputs requiring monitoring in their non-active state, such as extinguishing solenoids, beacons, horns, etc. Each driver is independent and has circuitry to monitor short and open circuits in field wiring.
view details

TS4000H - H2S Electrochemical Gas Detector

The TS4000H Intelligent Toxic Gas Detector continuously monitors hydrogen sulfide (H2S) in several ppm ranges, delivering highly accurate detection and protection. The unit features one person calibration and can virtually self-calibrate by simply activating a magnetic switch and applying gas. It provides status indication and alarm outputs. Configurations with relays, Modbus, and HART are available to meet many needs.
view details

ZN002A Three Zone Control Module

The ZN002A is a Zone Control Module for the Zero Two Series Fire and Gas Detection System. The ZN002A provides zoning and voting functions for three separate and independent zones of gas and / or flame detection.
view details

PS002 Power Supply

The PS002* power supply module provides sufficient power for 12 Zero Two Series Modules and their field devices. The PS002 slides into four channel slots and supplies the buss with +24 VDC. On the rear of the PS002, connections are provided for AC voltage in (line or neutral), for DC voltage in (battery backup), and for DC voltage out (+24 VDC). On the front panel there is a green LED for a Power ON indication. * Not available in Europe.
view details

Surveyor Ultrasonic Gas Leak Detector

The Surveyor detects gas leaks by sensing the airborne ultrasound emitted from leaking gas at high pressure. Ultrasonic gas detection is based on robust and proven Gassonic technology and designed for long and failsafe operation in extreme environmental conditions. Because the Surveyor responds to the source of a gas release rather than the dispersed gas, it is unaffected by changing wind directions, gas dilution, and the direction of the gas leak.
view details
Product Comparison Queue (0) Compare Products