Fixed Gas & Flame Detection

FL3100H-H2 UV/IR Flame Detector for Hydrogen Applications

The FL3100H-Hydrogen is an Ultraviolet / Infrared flame detector designed specifically to detect hydrogen (H2) fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects H2 fires by monitoring in both the ultraviolet (UV) and infrared (IR) spectral ranges, making it highly immune to false alarms. Configurations with dual Modbus and HART are available. Modbus and HART data can be used for predictive maintenance. The flame detector's electronics are integral within its explosion-proof housing, allowing detector information to be processed at the point of detection.
view details

TA202A Single Channel H2S Trip Amplifier Module

The TA202A is a single-channel H2S Trip Amplifier Module for use with our H2S Intelligent Sensors. It is designed to monitor H2S in parts per million (ppm) levels and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through front panel interface (mode / select switch and digital display).
view details

Ultima OPIR-5 Open Path Infrared Detector

Get continuous monitoring of methane, propane, and other combustible gases with this open path infrared detector. Provides 4-20 mA analog signals, as well as digital display and relay contacts. Digital display and adjustable mounting arms ensure easy alignment. Factory calibrated for low-maintenance operation.
view details

2280A Four Channel H2S Gas Monitor

The 2280A is a system for continuously monitoring H2S gas concentrations in four locations. The system consists of up to four remote mounted sensors and a solid state controller. The controller consists of four independent channels, each having its own circuitry. With a digital display, the 2280A shows hydrogen sulfide gas concentrations in ppm (parts per million) in the ranges of 0-20, 0-50, or 0-99 ppm for each channel.
view details

2602A Zero Two Series Control Module for H2S Applications

The 2602A is a single-channel H2S Control Module that has been designed to monitor H2S in parts per million (ppm) levels and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through front panel interface (mode / select switch and digital display). The digital display on the 2602A indicates hydrogen sulfide gas concentration, fault codes, calibration cues and setup options. Other features include LED indications of status, relay outputs for fault, low alarm and high alarm, and serial communications ports.
view details

FL3101H UV Flame Detector

The FL3101H is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. Configurations with dual Modbus and HART are available. Modbus and HART data can be used for predictive maintenance. The flame detector's electronics are integral within its explosion-proof housing, allowing detector information to be processed at the point of detection.
view details

IR Gas Detector Accessories

General Monitors offers a wide variety of accessories for infrared gas leak detection.
view details

H2S Gas Sensors and Accessories

General Monitorsʼ hydrogen sulfide (H2S) sensors are solid state devices, designed and manufactured for long life and fast response. They are selective to H2S and remain unaffected by high concentrations of other substances like hydrogen, sulfur dioxide, and gasoline vapors, which are often present in facilities that process sour gas and crude oil. A high tolerance to a broad range of temperatures and humidity enable these sensors to operate in rugged environments, as does their capacity to withstand exposure to high H2S concentrations over short periods.
view details

TA402A Single Channel Trip Amplifier

The Model TA402A is a single-channel trip amplifier module designed for use with the FL3100 Series Flame Detectors, providing status indication and alarm outputs.
view details

Electrochemical Sensors

The General Monitors electrochemical gas sensors are highly sensitive to toxic gases including carbon monoxide, H2S, hydrogen, hydrogen chloride, ammonia, chlorine, chlorine dioxide,  nitric oxide, nitrogen dioxide, ozone, SO2, and oxygen deficiency.
view details

FL802 Multi-Channel Flame Detection Readout / Relay Display Module

The Model FL802 is a compact, reliable and versatile multi-channel flame detection readout/relay display module designed to monitor up to eight remote FL4000H or FL3100 Series detectors.
view details

Observer-i Ultrasonic Gas Leak Detector

Instantly detect pressurized gas leaks with this high-precision,  omni-direction acoustic detector utilizing Gassonic ultrasonic technology. Works even when traditional methods of gas detection are unsuitable or dependent on ventilation. Features Artificial Neural  Network (ANN) technology that distinguishes between real gas leaks and false  alarm sources without requiring any in-field training. The Observer-i UGLD provides an industry-leading detection range (up to 28 m) reducing the  number of detectors required. Ideal for use in complex, outdoor pipeline systems.
view details

DC110 Eight Channel Combustible Readout / Relay Module

The DC110 is an eight-channel Readout / Relay Module designed to be used with up to eight of our remotely located Combustible Intelligent Sensors. The front panel contains a digital display that indicates 0-99% LEL (lower explosive limit) of the combustible gas being monitored by the Intelligent Sensors.
view details

TA502A Single Channel Trip Amplifier Module

The TA502A is a single-channel generic trip amplifier designed for use in Zero Two Series Gas and Flame Detection Systems. It is used to process the 0-22 mA signal from any field mounted transmitter.
view details

Toxic Gas Accessories

General Monitors offers a wide variety of accessories for our toxic gas detectors.
view details

CC02A Serial Communications Module

The CC02A Communications Card facilitates serial communications between each module in a Zero Two Series Flame and Gas Detection System and an external host computer, which allows fast access to operational and setup data registers. It supports a Burst Read feature that returns all registers of a module in a single transmission.
view details

DT210 Eight Channel H2S Readout / Relay Module

The DT210 is an eight-channel Readout / Relay Module designed for use with up to eight of our remotely located H2S Intelligent Sensors. The front panel contains a digital display that indicates 0-20 ppm (parts per million), 0-50 ppm, or 0-99 ppm of the hydrogen sulfide gas monitored by the Intelligent Sensors.
view details

RGC - Remote Gas Calibrator for Catalytic Bead Sensors

The Remote Gas Calibrator (RGC) allows calibration gas to be applied to a remotely located catalytic bead sensor from an easily accessible location. The RGC is used for blocking ambient air and redirecting methane to the catalytic sensor for calibration or testing sensor accuracy. The RGC tests or calibrates the General Monitors catalytic sensor with 50% LEL methane. The unit is capable of calibrating gas at wind velocities up to 50 mph. The RGC is used manually with a pressure regulator (P/N 80146-1) and is suitable for calibrating with any light hydrocarbon.
view details

TL105 Test Lamp

The TL105 is a battery operated test lamp designed specifically to test General Monitors Flame Detectors. The TL105 is an explosion-proof test lamp that can be used with the FL4000H MSIR flame detector as well as any of the FL3100 Series Flame Detectors. The TL105 operates up to 35 feet from the flame detector.
view details

FlameGard® 5 Test Lamp

With its high-energy broadband radiation source, the battery-operated FlameGard® 5 Test Lamp is precision-designed to test MSA's FlameGard® 5 MSIR, UV/IR, and UV/IR-H2 Flame Detectors. The rechargeable test lamp provides a radiation source that emits sufficient energy in both the ultraviolet and infrared spectra to activate UV and/or IR flame detectors. A variety of flashing test patterns allow the test lamp to check the operation of MSA flame detectors.
view details

FM002A Facilities Module

The FM002A is a facilities module that provides a range of common facilities for all Zero Two control modules housed in the chassis. The FM002A is plugged into the last slot on the right-hand side of the Zero Two chassis. It may be daisy-chained allowing one FM002A to serve up to 100 Zero Two modules in any combination.
view details

RGC-IR - Remote Gas Calibrator for Point IR Detectors

The remote gas calibrator, RGC-IR, is designed to be permanently installed on a combustible IR gas detector. The RGC-IR provides protection from outside elements and allows the user to apply calibration gas (@ 50 psi) to the detector from a remote source.
view details

Z-Gard® C 485 Controller

For wide-ranging gas-monitoring needs, the economical Z-Gard C 485 Controllers are up to the task. The controllers connect with a wide array of MSA Z-Gard S Sensors, with controller models accepting up to 24 sensors. Relay outputs indicate warning, alarm or sensor fail for each zone, and units are available with one or two zones. A large LED readout displays the active channel and the corresponding sensor gas level.
view details

IN042 Four Zone Control Module

The IN042 is a four zone input module designed for use with two-wire field devices such as smoke or heat detectors, pull switches and manual callpoints. It is designed to monitor these devices and provide both status indication and fault / alarm outputs for each zone.
view details

RGC-HT - Remote Gas Calibrator for High Temperatures

To verify the proper operation of a catalytic combustible gas sensor, it is necessary to periodically apply a gas of known concentration to the sensor. This is usually done manually at the site with gas supplied from a small lecture bottle. As the sensor reacts to the calibration gas, adjustments are made to the monitoring system to bring its calibration into agreement with the known concentration of the calibration gas. At times, sensors are mounted in inaccessible locations, requiring expensive catwalks or scaffolding to reach them. The High Temp Remote Gas Calibrator (RGC-HT) allows the calibration gas to be applied to the catalytic bead sensor from easily accessible locations. The RGC-HT is used for blocking ambient air and redirecting methane or other light hydrocarbon gases to the catalytic bead sensor for calibration or testing sensor accuracy in various environments. The RGC-HT tests or calibrates the General Monitors Catalytic Bead sensor with 50% LEL methane or other light hydrocarbon gas. The unit is capable of calibrating and detecting gases in various wind conditions (up to 45 mph) and temperatures (up to 200°C when used with high temperature sensor).
view details

TS4000H Toxic Gas Detector

The TS4000H Intelligent Toxic Gas Detector continuously monitors a variety of toxic gases in the ppm range or oxygen deficiency, delivering highly accurate detection and protection. The unit features one person calibration and virtually self-calibrates by simply activating a magnetic switch and applying gas. It provides status indication and alarm outputs. Configurations with relays, Modbus, and HART are available to meet many needs.
view details

ARGC - Automatic Remote Gas Calibrator

To verify the proper operation of a catalytic combustible gas sensor, it is necessary to periodically apply a gas of known concentration to the sensor. This is usually done manually at the site with gas supplied from a small lecture bottle. As the sensor reacts to the calibration gas, adjustments are made to the monitoring system to bring its calibration into agreement with the known concentration of gas. At times, sensors are mounted in inaccessible locations, requiring expensive catwalks or scaffolding to reach them. The Automatic Remote Gas Calibrator (ARGC) allows the calibration gas to be applied to the catalytic bead sensor from easily accessible locations. The ARGC is used for blocking ambient air and redirecting methane to the catalytic sensor for calibration or testing sensor accuracy. The ARGC tests or calibrates the General Monitors catalytic sensor with 50% LEL methane. The unit is capable of calibrating gas at wind velocities up to 50 mph. Note: the RGC (P/N 80153-1), used manually with a pressure regulator (P/N 80147-1), is suitable for calibrating with any light hydrocarbon.
view details

MD002 Monitored Driver Output Module

The MD002 is a monitored driver output module designed for four independent outputs requiring monitoring in their non-active state, such as extinguishing solenoids, beacons, horns, etc. Each driver is independent and has circuitry to monitor short and open circuits in field wiring.
view details

Quad Gas® II Controller

Housed in a rugged, NEMA 4X enclosure, this microprocessor-based system links with up to four remote gas sensors. The large, four-digit LED display shows gas concentration and features four warning relays with one per sensor. The model also comes with four discrete alarm relays. Warning, alarm set-points and full-scale range of the sensor are set at the user-friendly keyboard, while a DC battery connection provides backup stability.
view details

1701 Portable Test and Calibration Unit

The 1701 is a portable test and calibration unit used to verify the operation and calibrate certain ultrasonic gas leak detectors. Although the detectors do not require regular maintenance, the 1701 can be used to satisfy the requirements for regular plant maintenance. Further, the 1701 requires no electrical connection to the gas leak detector but is simply placed over the sensor head of the gas leak detector.
view details

TS4000H - H2S Electrochemical Gas Detector

The TS4000H Intelligent Toxic Gas Detector continuously monitors hydrogen sulfide (H2S) in several ppm ranges, delivering highly accurate detection and protection. The unit features one person calibration and can virtually self-calibrate by simply activating a magnetic switch and applying gas. It provides status indication and alarm outputs. Configurations with relays, Modbus, and HART are available to meet many needs.
view details

ZN002A Three Zone Control Module

The ZN002A is a Zone Control Module for the Zero Two Series Fire and Gas Detection System. The ZN002A provides zoning and voting functions for three separate and independent zones of gas and / or flame detection.
view details

IR4000S Single-Point Gas Monitor

The IR4000S Single-Point Monitor is a display and user interface for the IR400 point IR gas detector. The monitor allows local calibration and displays gas concentration. Relays are optional. The relays provide output for Alarm, Warn, and Fault conditions.
view details

Mounting Hardware

General Monitors offers a complete line of mounting hardware to facilitate installing any of our gas and flame detectors in commercial or industrial facilities.
view details

PS002 Power Supply

The PS002* power supply module provides sufficient power for 12 Zero Two Series Modules and their field devices. The PS002 slides into four channel slots and supplies the buss with +24 VDC. On the rear of the PS002, connections are provided for AC voltage in (line or neutral), for DC voltage in (battery backup), and for DC voltage out (+24 VDC). On the front panel there is a green LED for a Power ON indication. * Not available in Europe.
view details

IR4000M Multi-Point Gas Monitor

The IR4000M Multi-Point Gas Monitor can be used as an integrated combustible gas detection system, with capacity to connect eight point IR or open path gas detectors and read their status with one command. The highest current % LEL among all connected detectors is shown continuously during normal operation. An extensive set of menus are easily navigated using a magnetic switch to request the status and configuration data stored by the IR4000M.
view details

Toxgard® II Gas Monitor

Simply connect the convenient ToxGard II Gas Monitor to a power source and a remote sensor, and it's ready to detect toxic gases, combustible gases and oxygen deficiency. The indoor/outdoor unit is housed in a rugged NEMA 4X enclosure and features a large LED screen, three levels of alarm and a failsafe fault relay output.
view details

Chemgard® Photoacoustic Infrared Gas Monitor Series

The stable, durable Chemgard Photoacoustic Infrared Gas Monitor is purpose-built and detects minute amounts of a wide variety of gases. Three different enclosure styles ensure there is a configuration for wildly different situations. The instrument typically draws the gas sample via an internal pump, which allows the unit to be mounted in a convenient location if the area to be monitored is inaccessible. The unit can be expanded to monitor up to 8 locations, while an easy-to-read display shows gas concentrations and 3 levels of alarms.
view details

MultiGard™ 5000 Multipoint Gas Sampling System

The economical, efficient MultiGard 5000 Gas Sampling System uses auto-standardization and flexible sample point order to analyze gas from up to 32 locations. Maintenance and calibration are made easy because all the work is performed at a single location, while also ensuring personnel don't have to enter the monitored area. The unit directly connects to Modbus TCP/BACnet IP networks, which allows communication to other equipment or controllers. The system allows secure viewing at one's personal computer. The screen provides easy access to scroll-down menus and visual indicators of sensor condition.
view details

Chillgard® M-100

With its compact design and low-maintenance engineering, the Chillgard M-100 Refrigerant Sensor is easily mounted almost anywhere for trusted detection of halogenated refrigerant across a wide range of temperatures and humidity ranges—with a minimum detection level of 20ppm.
view details
Product Comparison Queue (0) Compare Products