Fixed Gas & Flame Detection

SB100 Ultrasonic Bump Tester

The SB100 is a hand-held battery-operated rechargeable ultrasonic tester designed to bump test General Monitors ultrasonic gas leak detectors. The SB100 is useful for quick tests where physical access to the ultrasonic gas detector can be difficult. The unit can be used to bump test up to 18 meters away from the detector in Class 1, Div 1&2 hazardous areas.
view details

MC600 Multi-Channel Controller

The MC600 is a microprocessor-based multi-channel controller that provides six channels of continuous gas detection. It can be configured as either a local gas detection system, or it can be networked to provide a large plant-wide distributed safety system. It is compatible with our hydrocarbon sensors, H2S sensors, as well as our S4000CH, S4100C, S4000TH, S4100T, IR400, IR5500, IR700, TS4000H, Observer, and Surveyor gas detectors.
view details

FL3100H UV/IR Flame Detector

The FL3100H is an Ultraviolet / Infrared flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It monitors in both the ultraviolet (UV) and infrared (IR) spectral ranges, making it highly immune to false alarms. Configurations with dual Modbus and HART are available. Modbus and HART data can be used for predictive maintenance. The flame detector's electronics are integral within its explosion-proof housing, allowing detector information to be processed locally.
view details

Zero Two Series Gas and Flame Detection System

Modular system offering the widest range of control cards for use in an integrated fire and/or gas detection system. The Zero Two Series system can monitor any combination of the following: combustible gas, H2S, toxic gas, ultrasonic, oxygen deficiency and flame detection. In addition, its open architecture allows the system to accommodate other sensing devices for tasks such as smoke detection, heat detection and manual call points. 
view details

610A Four Channel Combustible Gas Monitor

The 610A is a system for continuously monitoring combustible gas (hydrocarbon) concentrations in four locations. The system consists of four General Monitors remote catalytic bead sensing assemblies and a solid-state controller. The controller features four independent channels, each having its own circuitry. The 610A features a digital display of gas concentrations in % LEL (0-99% lower explosive limit) for each channel.
view details

Catalytic Bead Sensors

The General Monitors catalytic bead gas sensors are well known for their sensitivity, reliability and longevity and make them the first choice for most users of the catalytic oxidation gas detection principle. Every component is manufactured in-house to ensure optimum performance. Careful matching of the active and reference elements ("beads") result in a sensor that has negligible zero drift with respect to changes in humidity, pressure, and temperature.
view details

IR5500 Open Path Infrared Gas Detector

The IR5500 is an open path infrared (IR) gas detector that continuously monitors for flammable gas leaks over large open areas. It monitors in both the LEL-m and ppm-m ranges to detect both small and large leaks. The IR5500 offers the benefits of early detection with its high sensitivity to gas concentrations at the ppm levels.  This feature allows it to alarm faster than an LEL-only detector. Digital display and adjustable mounting arms ensure easy alignment. Factory calibrated for low-maintenance operation.
view details

580A Dual-Channel Combustible Gas Monitor

The 580A is a compact, highly-versatile system for continuously monitoring combustible gas (hydrocarbon) concentrations in two locations. The system consists of two remote catalytic sensing assemblies and a solid-state controller. The controller automatically displays the higher reading channel on a digital display, scaled from 0-100% LEL (lower explosive limit). Manual override switching permits readout of the low channel at any time.
view details

Catalytic Bead Accessories

General Monitors offers a wide variety of accessories for our catalytic bead gas sensors.
view details

FL3100H-H2 UV/IR Flame Detector for Hydrogen Applications

The FL3100H-Hydrogen is an Ultraviolet / Infrared flame detector designed specifically to detect hydrogen (H2) fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects H2 fires by monitoring in both the ultraviolet (UV) and infrared (IR) spectral ranges, making it highly immune to false alarms. Configurations with dual Modbus and HART are available. Modbus and HART data can be used for predictive maintenance. The flame detector's electronics are integral within its explosion-proof housing, allowing detector information to be processed at the point of detection.
view details

FL3101H UV Flame Detector

The FL3101H is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. Configurations with dual Modbus and HART are available. Modbus and HART data can be used for predictive maintenance. The flame detector's electronics are integral within its explosion-proof housing, allowing detector information to be processed at the point of detection.
view details

IR Gas Detector Accessories

General Monitors offers a wide variety of accessories for infrared gas leak detection.
view details

H2S Gas Sensors and Accessories

General Monitorsʼ hydrogen sulfide (H2S) sensors are solid state devices, designed and manufactured for long life and fast response. They are selective to H2S and remain unaffected by high concentrations of other substances like hydrogen, sulfur dioxide, and gasoline vapors, which are often present in facilities that process sour gas and crude oil. A high tolerance to a broad range of temperatures and humidity enable these sensors to operate in rugged environments, as does their capacity to withstand exposure to high H2S concentrations over short periods.
view details

Electrochemical Sensors

The General Monitors electrochemical gas sensors are highly sensitive to toxic gases including carbon monoxide, H2S, hydrogen, hydrogen chloride, ammonia, chlorine, chlorine dioxide,  nitric oxide, nitrogen dioxide, ozone, SO2, and oxygen deficiency.
view details

Observer-i Ultrasonic Gas Leak Detector

Instantly detect pressurized gas leaks with this high-precision,  omni-direction acoustic detector utilizing Gassonic ultrasonic technology. Works even when traditional methods of gas detection are unsuitable or dependent on ventilation. Features Artificial Neural  Network (ANN) technology that distinguishes between real gas leaks and false  alarm sources without requiring any in-field training. The Observer-i UGLD provides an industry-leading detection range (up to 28 m) reducing the  number of detectors required. Ideal for use in complex, outdoor pipeline systems.
view details

Toxic Gas Accessories

General Monitors offers a wide variety of accessories for our toxic gas detectors.
view details

RGC - Remote Gas Calibrator for Catalytic Bead Sensors

The Remote Gas Calibrator (RGC) allows calibration gas to be applied to a remotely located catalytic bead sensor from an easily accessible location. The RGC is used for blocking ambient air and redirecting methane to the catalytic sensor for calibration or testing sensor accuracy. The RGC tests or calibrates the General Monitors catalytic sensor with 50% LEL methane. The unit is capable of calibrating gas at wind velocities up to 50 mph. The RGC is used manually with a pressure regulator (P/N 80146-1) and is suitable for calibrating with any light hydrocarbon.
view details

TL105 Test Lamp

The TL105 is a battery operated test lamp designed specifically to test General Monitors Flame Detectors. The TL105 is an explosion-proof test lamp that can be used with the FL4000H MSIR flame detector as well as any of the FL3100 Series Flame Detectors. The TL105 operates up to 35 feet from the flame detector.
view details

TS4000H Toxic Gas Detector

The TS4000H Intelligent Toxic Gas Detector continuously monitors a variety of toxic gases in the ppm range or oxygen deficiency, delivering highly accurate detection and protection. The unit features one person calibration and virtually self-calibrates by simply activating a magnetic switch and applying gas. It provides status indication and alarm outputs. Configurations with relays, Modbus, and HART are available to meet many needs.
view details

ARGC - Automatic Remote Gas Calibrator

To verify the proper operation of a catalytic combustible gas sensor, it is necessary to periodically apply a gas of known concentration to the sensor. This is usually done manually at the site with gas supplied from a small lecture bottle. As the sensor reacts to the calibration gas, adjustments are made to the monitoring system to bring its calibration into agreement with the known concentration of gas. At times, sensors are mounted in inaccessible locations, requiring expensive catwalks or scaffolding to reach them. The Automatic Remote Gas Calibrator (ARGC) allows the calibration gas to be applied to the catalytic bead sensor from easily accessible locations. The ARGC is used for blocking ambient air and redirecting methane to the catalytic sensor for calibration or testing sensor accuracy. The ARGC tests or calibrates the General Monitors catalytic sensor with 50% LEL methane. The unit is capable of calibrating gas at wind velocities up to 50 mph. Note: the RGC (P/N 80153-1), used manually with a pressure regulator (P/N 80147-1), is suitable for calibrating with any light hydrocarbon.
view details

TS4000H - H2S Electrochemical Gas Detector

The TS4000H Intelligent Toxic Gas Detector continuously monitors hydrogen sulfide (H2S) in several ppm ranges, delivering highly accurate detection and protection. The unit features one person calibration and can virtually self-calibrate by simply activating a magnetic switch and applying gas. It provides status indication and alarm outputs. Configurations with relays, Modbus, and HART are available to meet many needs.
view details

IR4000S Single-Point Gas Monitor

The IR4000S Single-Point Monitor is a display and user interface for the IR400 point IR gas detector. The monitor allows local calibration and displays gas concentration. Relays are optional. The relays provide output for Alarm, Warn, and Fault conditions.
view details

IR4000M Multi-Point Gas Monitor

The IR4000M Multi-Point Gas Monitor can be used as an integrated combustible gas detection system, with capacity to connect eight point IR or open path gas detectors and read their status with one command. The highest current % LEL among all connected detectors is shown continuously during normal operation. An extensive set of menus are easily navigated using a magnetic switch to request the status and configuration data stored by the IR4000M.
view details

IR700 Point IR Carbon Dioxide Gas Detector

The IR700 Infrared (IR) Point Detector is a microprocessor-based carbon dioxide gas detector that continuously monitors for CO2 in ppm levels. All electronics are contained within an explosion-proof housing so that the IR700's detector information can be processed locally. The IR700 operates with a 4-20 mA signal, which is proportional to 0 to 100% full scale. Configurations with analog output, Modbus and HART are available. Modbus and HART data can be used for predictive maintenance.
view details

IR4000S-CO2 Single Point Gas Monitor

The IR4000S CO2 Single-Point Monitor is a display and user interface for the IR700 carbon dioxide gas detector. The monitor allows local calibration and displays gas concentration. Relays are optional. The relays provide output for Alarm, Warn, and Fault conditions. 
view details

Surveyor Ultrasonic Gas Leak Detector

The Surveyor detects gas leaks by sensing the airborne ultrasound emitted from leaking gas at high pressure. Ultrasonic gas detection is based on robust and proven Gassonic technology and designed for long and failsafe operation in extreme environmental conditions. Because the Surveyor responds to the source of a gas release rather than the dispersed gas, it is unaffected by changing wind directions, gas dilution, and the direction of the gas leak.
view details
Product Comparison Queue (0) Compare Products