- Self-diagnostics - continuously perform system tests to watch for any faults
- Wide Field of View - 120 degree scan across a facility with a wide scope reduces the need for additional flame detectors
- State-of-the-Art Fire Algorithms - analyzes data from the system array for individual intensity values, change of intensity values, relationship of intensity values, and frequency signature correlation
- Tri-Spectra Design - detects both hydrocarbon and non-hydrocarbon flames and rejects false alarms
- Through-the-Lens Test - continuous test performed to validate a clean lens for proper function
- Micro-processor Decision-Making - stores pre-fire spectral data in non-volatile memory and outputs an alarm signal in the form of a relay transition
- Enhanced Relay Models - includes a second alarm relay for alarm verification purposes (optional)
Sensitivity
- 1 sq. ft. pan fire on axis ~ 80 feet within 5 seconds(using standard fuel)
- Switch selectable from 20 to 80 feet to a sq. ft. kerosene fire
Field of View
Responsivity
- UV – 180 to 260 nm
- IR – 0.715 to 3.5 microns
- Visible – 480 to 560 nm
Input Voltage
- 15 to 32 volts, typically 24 volts
Current Draw
- @ 24 volts DC: 72 mA normal mode, 82 mA alarm mode
Temperature Range
- Operating: -40oF to 185oF (-40oC to 85oC)
- Storage: -67oF to 230oF (-55oC to 110oC)
LEDs
- Display switch settings, fault type, fire and verified fire information
Relays
- Model 3100-01: Fire and Fault Relays
- Fire Relay: 0.5 amp ~ 120 VAC, 1.0 amp @ 24 VDC resistive, normally open and normally closed contacts, latching or fire-following nodes
- Fault Relay: 0.5 amp ~ 120 VAC, 1.0 amp ~ 24 VDC resistive, normally open, common and normally closed contacts
- Enhanced Relay Models: Fire, Fault Verify and Aux Relays
- Verify Relay: 0.5 amp ~ 120 VAC, 1.0 amp ~ 24 VDC resistive, normally open and normally closed contacts are available. May be operated in either a latching or fire following mode.
- Aux Relay: 0.5 amp ~ 120 VAC, 1.0 amp ~ 24 VDC resistive, normally open and normally closed contacts are available. Normally used to indicate a Lens Check Fault.
Enclosure
- Copper-free cast aluminum with epoxy finish
Hazardous Area Classification
- NEMA 4X Enclosure rating, Explosion Proof
- Class 1, Div. 1 and 2, Groups B, C, D, Class II, Div. 1 and 2, Groups E, F, G, Class III
Dimensions
- 5.4 x 4.8 x 3.7 inches (13.7 x 12.2 x 9.4 cm)
Weight
Approvals subject to change without notice and may differ based on configuration, part number and/or country.
Contact Customer Service or check approval label on product for specific approval information.