View Part Numbers Configure this product

 All ALTAIR 2X Gas Detectors

  • Incorporate proven XCell® sensor technology
  • Enhance worker safety, compliance and traceability
  • Minimize cost of ownership
  • Demonstrate rugged durability
 
Product Options
  • ALTAIR 2XP Gas Detector with XCell Pulse Technology: H2S  -
    • Features the first stand-alone bump test, which eliminates the need for bottled gas!
    • Bump test anytime, anywhere
    • Based on proven science and patented sensor capabilities
  • ALTAIR 2XP Gas Detector with XCell Pulse Technology: H2S
  • ALTAIR 2X Gas Detectors: CO, CO-HC (High Concentration), CO-H2 (Hydrogen Resistant), H2S-LC, SO2, NO2, NH3 and Cl2
  • ALTAIR 2XT Two-Tox Gas Detector: CO/H2S, CO-H2/H2S, CO/H2S-LC, CO/NO2 and SO2/H2S-LC
Safety io compatible product

Part Number
Description

ALTAIR® 2XT, SO2/H2S-LC (SO2: 2, 5; H2S: 10, 15), Charcoal

Length: 2.126 IN (54.000 MM)
Width: 2.362 IN (60.000 MM)
Height: 3.465 IN (88.000 MM)
Weight: 0.243 LB (0.110 KG)
Color: GRAY

ALTAIR® 2X, CO (25, 100), Charcoal

Length: 2.008 IN (51.000 MM)
Width: 2.402 IN (61.000 MM)
Height: 3.465 IN (88.000 MM)
Weight: 0.243 LB (0.110 KG)
Color: GRAY

Detector, ALTAIR 2XT, CO/H2S-LC, Gray

Length: 3.425 IN (87.000 MM)
Width: 2.165 IN (55.000 MM)
Height: 1.850 IN (47.000 MM)
Weight: 0.243 LB (0.110 KG)
Color: GRAY

ALTAIR® 2X, CO-HC (25, 100), Charcoal

Length: 2.126 IN (54.000 MM)
Width: 2.362 IN (60.000 MM)
Height: 3.504 IN (89.000 MM)
Weight: 0.243 LB (0.110 KG)
Color: GRAY

ALTAIR® 2X, CI2 (0.5, 1), Charcoal

Length: 2.126 IN (54.000 MM)
Width: 2.480 IN (63.000 MM)
Height: 3.465 IN (88.000 MM)
Weight: 0.243 LB (0.110 KG)
Color: GRAY

ALTAIR® 2XT, CO/NO2 (CO: 25, 100; NO2: 2.5, 5), Glow-In-The-Dark

Length: 2.126 IN (54.000 MM)
Width: 2.402 IN (61.000 MM)
Height: 3.465 IN (88.000 MM)
Weight: 0.243 LB (0.110 KG)
Color: GLOW

Low cost of ownership

  • Fastest sensor response times, lowest calibration gas flow rate on the market
  • > 4-year expected sensor life
  • 3-year warranty on instrument & most sensors (2 years on Cl2, NH3)
  • Stand-alone bump tests reduce maintenance, increase productivity (ALTAIR 2XP only)
  • 1 device can monitor 2 gases (ALTAIR 2XT only)

Increased safety awareness & compliance

  • Stand-alone bump test anytime, anywhere without specific calibration gas (ALTAIR 2XP only)
  • Bump pass: green LED flash every 15s, large on-screen checkmark
  • Bump fail or expiration: red LED flash every 15s, no checkmark
  • End-of-sensor-life warning and alarm

Full-time traceability

  • Records 75 alarm events
  • 150+ hours of periodic data (ALTAIR 2X and 2XP)
  • 100+ hours of periodic data (ALTAIR 2XT)
  • Compatible with MSA GALAXY® GX2 Automated Test System and MSA Grid

Rugged durability

  • Tough over-molded rubber armor
  • Survives multiple 25-ft drops onto concrete
  • Agency-certified dust- and water-tight IP67 construction
  • Intrinsically-safe design
Markets: Construction, Fire Service, General Industry, Oil & Gas, Utilities
Applications: Confined Space, Turnarounds & Plant Maintenance